ADC HDSL4 Bedienungsanleitung Seite 14

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 38
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 13
Table 7: 1 in 8 TEST PATTERN FOR B8ZS LINE CODING
Pattern Average Ones Dens-
ity
Maximum Zeros Circuit Stressed
1 in 8 (un-framed) 12.5% 7 Timing
1 in 8 (framed)* 12.5% 8 Timing
*When the 1 in 8 bit pattern is sent with framing bits, the 1 bit must be located in the second position to prevent a
yellow alarm or excessive zero condition.
5.5. 3 in 24 PATTERN
This pattern simultaneously stresses both the minimum ones density and the maximum number of consecutive zeros.
This sequence is useful for testing the timing recovery circuit of the repeater. When framed, the frame bit must be
located in the position identified, or either a yellow alarm or a sequence of 16 zeros will occur. This test pattern is used
to test the minimum ones density for an AMI line code.
. . . 0100 F 01000100 00000000 00000100 01000100. . .
Table 8: 3 in 24 TEST PATTERN FOR AMI LINE CODING
Pattern Average Ones Dens-
ity
Maximum Zeros Circuit Stressed
3 in 24 (un-framed) 12.5% 15 Timing
3 in 24 (framed)* 12.5% 15 Timing
The frame bit location must be as specified to prevent a D4 yellow alarm or excessive zero condition.
5.6. ALL ONES
This sequence is useful for stressing the regenerator circuit of a repeater. When received, the all ones sequence
causes the repeater to consume the maximum amount of power. If inadequate, DC power is provided by the office
repeater through the simplex current path, which may cause the repeater to drop out.
AT&T Practice ATT-TP-000-000-006
Issue 1, 08/25/06
2006 AT&T Knowledge Ventures. All rights reserved
12
Seitenansicht 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 37 38

Kommentare zu diesen Handbüchern

Keine Kommentare